Description
Magpar exits before the end of the simulation when the option -hext_ho_hstepfile is used.
Bug reported by Dr. Han - thank you!
Steps to reproduce
- Run magpar simulation with any inp file and input files given below.
- magpar exits at Hext=0 with the message "hextamp 0 kA/m exceeds hextfinal 0 kA/m"
Details
magpar version |
0.8 (original) |
OS and version |
any |
Compiler name and version |
any |
Machine/hardware/CPU type |
any |
Library versions |
any |
allopt.txt:
-simName nanotube -meshtype 1 -size 1e-9 -inp 0001 -init_mag 8 -mode 1 -demag 1 -hextini 1591.5494 -htheta 1.5707963 -hphi 0 -hext_ho_hstepfile Hstep.txt -condinp_equil 1 -slice_n 0,0,1 -slice_p 0,0,5 -tol 1e-6 -tao_monitor
Hstep.txt
9 1 1 2 0.4 3 0 4 -0.6 5 -1 6 -0.6 7 0 8 0.5 9 1
Workaround
No really useful workaround available. Try "-hstep" option instead of using "-hext_ho_hstepfile" - not a full replacement though.
Bug fix available: hext_ho.c
Plan
- Priority: high
Assigned to: WernerScholz
- Status: fixed: fixed in development version leading up to version 0.9